Surgical Drape
- Ningún producto.:MD-300
Descripción del producto
AFC® Surgical drape is composed of AFC® Medical & Healthy fabric, and both fabric and drape conform to EN 13795 European Guideline and AAMI PB-70 US Guideline. A surgical drape has multi-layers that providing multi-function and protections to patients and personnel, which can reduce the risk of Hospital-acquired infection (HAI). The bottom layer of drapes is polyester-based and processed with high water repellency, hence it is reusable, non-linting and impervious. The upper layer of drapes adopts high absorbent fabric that can pick up and remain operative fluid and skin flora adjacent to operative site. Additionally, the entire drape presents excellent anti-slip, abrasion, puncture resistance, anti-static property and durable to several times of laundry, drying, auto-clave, to create an area of sterile field for each utilization.
Especificaciones
Opción de tejido base
Artículo de tela | Composición | Tejido y peso |
---|---|---|
T02 | 99% Polyester Filament Yarn
1% Polyester Conductive Yarn High Water Repellency |
2/2 Twill, 5mm stripe 206 g/y (148 g/m2) 60 inch (152 cm) |
T68 | 1/1 Plain, 8mm stripe 184 g/y (123 g/m2) 64 inch (163 cm) | |
T05 | Plain, 8mm stripe 202 g/y (140 g/m2) 62 inch (157 cm) | |
T03 | 98% Polyester Filament Yarn
2% Polyester Conductive Yarn |
1/1 Plain, 8mm Rip-stop 192 g/y (127g/m2) 64 inch (163 cm) |
T04 | Face Fabric : 100% Polyester
Membrance : PTFE Bottom Fabric : 100% Polyester |
3 Layer Fabric 264 g/y (199 g/m2) 57 inch (145 cm) |
Opción de tejido de alta absorción
CK10 | 100% Polyester Filament Yarn | 400 g/y (265 g/m2) 65 inch (165 cm) |
R-2702 | 330 g/y (240 g/m2)±5%, 60 inch (152 cm)±1 |
Opción de tejido base :
T02、T68、T05、T03、T04
Alta absorción :
CK10、R-2702
Caracteristicas
- Comply with EN 13795 European Guideline and AAMI PB-70 US Guideline
- Processed with high water repellency, effectively reducing the risk of HAI
- Bottom fabric brings highly rugged, non-linting and fluid impermeability
- Upper fabric presents high absorption, effectively picking up operative fluid
- Strengthened adhesion, abrasion, puncture resistance, anti-static property
- Durable to high temperature laundry and sterilization procedure, e.g. auto-clave
Sugerencias y precauciones
- Processed with laundry, drying and auto-clave procedure to reach better Ingress Protection, and estimated to use maximum 100 times
- The maximum times of use determines by individual conditions, only suggested no more than 100 times
- Ironing temperature does not exceed 130℃
- Do not use once damage found